System management > flags, System management > power up, System management > lvds backlight – ADLINK Express-BE User Manual

Page 51: System management > smart fan, System date and time, Advanced

Advertising
background image

Express-BE

Page 51

7.2.3.5.

System Management > Flags

Feature

Options

Description

Flags Info

only

BMC

Flags

Read

only

BIOS Select

Read only

Display the selection of current BIOS ROM

ATX/AT-Mode Read

only

Display

ATX/AT-Mode

Exception Code

Read only

System exception reason

7.2.3.6.

System Management > Power Up

Feature

Options

Description

Power Up

Info only

Power Up watchdog

Attention: F12 disables the Power Up
Watchdog.

Enabled
Disabled

The Power-Up Watchdog resets the system after a certain
amount of time after power-up.

ECO

Mode

Disabled
Enable

Reduces the power consumption of the system

Power-up

Mode

Attention: The Power-Up Mode only has
effect, if the module is in ATX-Mode.

Turn on
Remain off
Last State

Turn On: The machine starts automatically when the power
supply is turned on.
Remain Off: To start the machine the power button has to be
pressed.
Last State: When powered on during a power failure the system
will automatically power on when power is restored.

7.2.3.7.

System Management > LVDS Backlight

Feature

Options

Description

LVDS Backlight

Info only

LVDS Backlight Bright

255

The value range starts at 0 and ends at 255.

7.2.3.8.

System Management > Smart Fan

Feature

Options

Description

Smart Fan

Info only

CPU Smart FanTemperature

Source

CPU Sensor
System Sensor

Select CPU smart fan source

CPU Fan Mode

AUTO (Smart Fan)
Fan Off
Fan On

Select CPU fan mode

CPU Trigger Point 1

Read only

Trigger Temperature

15

Specifies the temperature threshold at which the BMC turns on
the CPU fan with the specified PWM level

PWM Level

30

Select PWM level

CPU Trigger Point 2

Read only

Trigger Temperature

60

Specifies the temperature threshold at which the BMC turns on

Advertising