Advanced Control Technologies Specs Instructions ZTH210 (RF Controller, HandheldLED Indicator, 868.42MHz) User Manual

Page 15

Advertising
background image

ZTH200 Operating Instructions (Version 1.26)

P/D 102406

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

15

If instead you press OK, you will be directed to the thermostat modes of control (i.e.. Cooling, Heating, etc.).
In each case, the remote will retrieve the current setting of the thermostat and then allow you to change that setting
(depending on what is supported by the thermostat).

4.4.3 THERMOSTAT MODES

The ZTH200 supports HEAT MODE, COOL MODE, AUTO MODE, AUTO CHANGEOVER MODE, DRY AIR MODE,
FAN MODE ONLY, FURNACE MODE, MOIST AIR MODE. Scroll left or right to select. After you have changed the
setting, press OK.

If setting was recorded, display will say “Mode Successful”. If not it will say “Comm. Failed”, in which case reorient
the ZTH200 and try again.

4.4.4 THERMOSTAT SETPOINT

The ZTH200 supports sending set points from 55

o

F to 90

o

F and from 12

o

C to 32

o

C. Scroll left or right to select desired

set point.

The ZTH200 will display set points from 40

o

F to 90

o

F or from 4

o

C to 32

o

C. Above and Below those limits and the ZTH200

will display > Max or < Min. After you have changed the setting, press OK. If setting was recorded, display will say
“Setpoint Successful”. If not it will say “Comm. Failed”, in which case reorient the ZTH200 and try again.

4.4.5 FAN MODES

The ZTH200 supports FAN MODE AUTO (high), FAN MODE ON (high), FAN MODE AUTO (low), FAN MODE ON
(low). Scroll left or right to select. After you have changed the setting, press OK.

Advertising