Advanced Control Technologies Specs Instructions ZTH210 (RF Controller, HandheldLED Indicator, 868.42MHz) User Manual

Page 17

Advertising
background image

ZTH200 Operating Instructions (Version 1.26)

P/D 102406

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

17

REMOVE ASSOCIATION
Used when you want to remove an association in a unit . The unit in which the association is removed is the source
module and the unit being removed is the destination module. When you select “Remove Association”, you will be
prompted to select a group number.

What each group does is solely dependent upon the source module. What each group is sent is also dependent upon
source module. Refer to the instructions that came with the source module.
Once the group number is selected (using the arrow buttons), press OK.
Now you will be prompted to “Press button on Destin.”. This indicates you should now press button on the destination
module. Refer to instructions of destination module on exactly what to do in this situation as you may have to do more
than simply pressing a button.
When the ZTH200 receives the destination module ID, it will then request you “Press Button on Source”. Refer to
instructions of source module on exactly what to do in this situation as you may have to do more than simply pressing
a button. After you have pressed the button on the source module, the ZTH200 will either show “Successful” or
“Comm. Failed”. If the ZTH200 shows “Comm. Failed”, simply try again or move closer to source module and try
again.

REQUEST ASSOCIATION
If you desire to determine what modules a source module sends to, this function will allow you to determine that
information.
When you select “Request Association”, you will be prompted to select a group number.

This group number is the group within the source module in which the destination module will be placed in when
associated. What each group is sent and does is solely dependent upon the source module. Refer to the instructions
that came with the source module.

Once the group number is selected either using the arrow buttons, press OK.

Now you will be prompted to “Press Button on Unit” . Refer to instructions of module on exactly what to do in this
situation as you may have to do more than simply pressing a button.

When the ZTH200 receives the information from the unit, the ZTH200 will either show:

Use the arrows to show the units in the group.

Or it will show:

Which indicates the group is empty in the ZTH200.

Pressing the OK button at this point will also show you how many modules the group can support.

If the ZTH200 requests the association settings but does not receive information from the unit, the ZTH200 will simply
show “Request Sent” until the ZTH200 receives the information, goes to sleep, or you press the CLEAR button.

Advertising