Setup Options.

OPERATION

FUNCTION

DUMP DELAY

This mode controls the dump valve. (If fitted).

The dump delay is used to set the dump valve to dump 40 seconds after the pump is

turned off or can be set to dump one hour after the pump has turned off.

After 40 seconds or 1 hour the base is drained and left dry until the next cycle.

PRE-COOL

The pre-cool feature is used to let the pump wet the pads for 1.5 minutes before the

controller turns the fan on.

This feature applies to COOL and THERM modes on Touch Pad.

This feature applies to the COOL and AUTO modes on Programmable Control.

The pre-cool can be selected to be either on or off.

DUMP INTERVAL

The dump interval is used to cycle the dump valve (if fitted) in 1, 2, 4, 8, 12, and 24 hour

cycles. If the unit is on for long periods of time or the water has a high mineral content a

dumping interval can be set to help maintain the unit.

When the dumping time interval has timed out, (eg.: after 4 hours of pump operation) the

unit will shut down for 2 minutes while the dump valve drains the water from the base.

After 1.5 minutes the dump valve is closed, the base fills with water and the unit starts in
the same mode that it was in before the dumping cycle commenced.

PRE-FILL

The pre-fill mode allows the base to be filled with water (if a dump valve has been fitted)

for 1 minute before starting the pump and can be set to the on or off mode.