Reclaim antifreeze, Jt922 operator’s manual – Ditch Witch JT922 User Manual
Page 124
Advertising
JT922 Operator’s Manual
Complete the Job - 123
Antifreeze Drilling Unit
CMW
Reclaim Antifreeze
1.
Start drilling unit and run at low throttle.
2.
Move carriage to front of drill frame.
3.
Position 3-gal (11-L) bucket under spindle.
4.
Turn drilling fluid pump on low speed.
5.
Turn drilling fluid pump off when drilling fluid comes out of spindle.
6.
Pour antifreeze into onboard tank.
IMPORTANT: Antifreeze can be removed from antifreeze tank and disposed of properly or it can be
reused until it is too diluted with drilling fluid to protect against freezing.