Manual – Ditch Witch JT922 User Manual

Page 60

Advertising
background image

Manual

Prepare - 59

Plan Bore Path

CMW

Pipe-By-Pipe Bend Limits

Pipe

(C)

Forward (B)

Deflection (A)

Pipe

(C)

Forward (B)

Deflection (A)

1

6 ft 0 in (1.8 m)

0 ft 2 in (0.1 m)

15

79 ft 5 in (24.3 m)

36 ft 3 in (11.1 m)

2

12 ft 0 in (3.7 m)

0 ft 8 in (0.2 m)

16

83 ft 2 in (25.4 m)

40 ft 11 in (12.5 m)

3

17 ft 11 in (5.5 m)

1 ft 6 in (0.5 m)

17

86 ft 8 in (26.2m)

45 ft 9 in (13.9 m)

4

23 ft 9 in (7.2 m)

2 ft 9 in (0.8 m)

18

89 ft 11 in (27.4m)

50 ft 10 in (15.5 m)

5

29 ft 7 in (9 m)

4 ft 3 in (1.3 m)

19

92 ft 11 in (28.3m)

56 ft 0 in (17 m)

6

35 ft 4 in (10.8 m)

6 ft 1 in (1.8 m)

20

95 ft 6 in (29.2m)

61 ft 5 in (18.7 m)

7

40 ft 11 in (12.5 m)

8 ft 3 in (2.5 m)

21

97 ft 10 in (29.9m)

66 ft 11 in (20.4 m)

8

46 ft 4 in (14.1 m)

10 ft 9 in (3.2 m)

22

99 ft 11 in (30.5m)

72 ft 7 in (22.2 m)

9

51 ft 8 in (15.7 m)

13 ft 7 in (4.2 m)

23

101 ft 7 in (31m)

78 ft 4 in (23.9 m)

10

56 ft 9 in (17.3 m)

16 ft 8 in (5.1 m)

24

102 ft 11 in (31.4m)

84 ft 2 in (25.7 m)

11

61 ft 9 in (18.8 m)

20 ft 1 in (6.2 m)

25

103 ft 11 in (31.7m)

90 ft 1 in (27.5 m)

12

66 ft 6 in (20.3 m)

23 ft 9 in (7.2 m)

26

104 ft 7 in (31.9m)

96 ft 1 in (29.4 m)

13

71 ft 0 in (21.6 m)

27 ft 8 in (8.4 m)

27

105 ft 0 in (32m)

102 ft 1 in (31.2 m)

14

75 ft 4 in (23 m)

31 ft 10 in (9.8 m)

27.5

105 ft 0 in (32m)

105 ft 0 in (32 m)

Pipe 14 is illustrated.

Advertising