Vacuum boom, 250 hour, Vacuum system – Ditch Witch FXT60 User Manual

Page 112

Advertising
background image

FX60/FXT60 Tier 4 Operator’s Manual

Service - 111

250 Hour

CMW

®

Vacuum Boom

Check Structure

Check boom deflector every 100 hours. Replace as needed.

250 Hour

Vacuum System

Change Engine Oil and Filter

Change oil and filter after 250 hours and every
250 hours if using oil meeting API CJ-4 or ACEA
E6/E9. See page 88 for more information about
DEO specifications.

1.

Drain crankcase through drain valve (1) while
oil is warm.

2.

Replace filter (2) each time oil is changed.

3.

Add 8.5 qt (8 L) of DEO at fill neck (4).

4.

Verify correct oil level at dipstick (3).

Location

Task

Notes

Vacuum
System

change engine oil and filter

DEO, initial and if using API
CJ-4 or ACEA E6/E9 oil

Inspect air intake system

Advertising
This manual is related to the following products: