background image

FX60/FXT60 Tier 4 Operator’s Manual

Vacuum and Pothole - 77

Unload to Another Tank

CMW

®

4.

Open offboard tank inlet valve. Move valve handle counterclockwise to engage “reverse flow” mode
and start engine. Material will flow into offboard tank.

5.

Increase throttle as desired to transfer material.

6.

When transfer is complete, throttle down completely and turn off engine. Close FX tank drain/outlet
valve.

7.

Close offboard tank inlet valve and disconnect hose from offboard tank inlet valve.

8.

Move handle clockwise to “vacuum” mode and turn on engine.

9.

Open FX tank drain/outlet valve. Material will empty from transfer hose.

10. Close FX tank drain/outlet valve, throttle down and turn off engine.

11. Disconnect transfer hose from FX tank.