Vacuum system – Ditch Witch FXT60 User Manual

Page 95

Advertising
background image

Service - 94

FX60/FXT60 Tier 4 Operator’s Manual

10 Hour

CMW

®

Vacuum System

Check Engine Oil Level

Check engine oil at dipstick (1) before operation
and every 10 hours thereafter. Check with unit on
level surface and at least 15 minutes after
stopping engine. Add DEO at fill (2) as necessary
to keep oil level at highest line on dipstick.

Drain Fuel/Water Separator

Drain water out of filter every 10 hours. To drain,
place loose end of drain hose into approved
container. Turn valve on bottom of filter
counterclockwise 4 turns until water flows out of
drain hose. When fuel comes out, turn valve
clockwise to close.

Inspect Belts

Check fan (2), blower (1), and water pump (3)
belts every 10 hours for damage or wear.

Advertising
This manual is related to the following products: