500 hour, Vacuum system – Ditch Witch FXT60 User Manual

Page 113

Advertising
background image

Service - 112

FX60/FXT60 Tier 4 Operator’s Manual

500 Hour

CMW

®

Inspect Air Intake System

Inspect intake piping for cracked hoses, loose
clamps, or punctures. Tighten or replace parts as
necessary.

500 Hour

Vacuum System

Change Engine Oil and Filter

Change oil and filter every 500 hours ONLY if
using oil meeting Deutz DQC III- LA. See page 88
for more information about DEO specifications.

1.

Drain crankcase through drain valve (1) while
oil is warm.

2.

Replace filter (2) each time oil is changed.

3.

Add 8.5 qt (8 L) of DEO at fill neck (4).

4.

Verify correct oil level at dipstick (3).

Location

Task

Notes

Vacuum
System

Change engine oil and filter

DEO; ONLY if using DQC III-
LA oil

Change fuel filters and clean filter screen

Advertising