Open/close tank door, Standard door, Mv800 operator’s manual – Ditch Witch MV800 User Manual

Page 53

Advertising
background image

Vacuum and Pothole - 52

MV800 Operator’s Manual

Open/Close Tank Door

CMW

®

Open/Close Tank Door

Standard Door

Open

1.

If using optional reverse flow mode, turn off
engine and ensure handle is down (in
“vacuum” mode).

2.

If tank is tilted, lower tank fully before opening
door.

3.

Open tank inlet valve.

4.

Turn handles (1) counterclockwise until door
latches are free. Rotate latches away from
tank.

Close

1.

Close door.

2.

Close tank inlet valve.

3.

Pull stop pin (2) up and rotate door latches toward tank.

4.

Turn handles (1) clockwise until door touches seal on both sides.

5.

Repeat tightening until both door latches are tight.

Crushing weight could cause death or serious injury. Stay

away.

275-326

To help avoid injury: Do not raise tank with door held closed only by vacuum. Door may suddenly
open and possibly injure someone.

NOTICE: Do not drive with tank or door raised.

IMPORTANT: Depressurize tank before emptying vacuum air filter canister, cleaning filter, clearing
hoses or opening any doors.

Advertising