Service - 88
MV800 Operator’s
Manual
As Needed
CMW
®
Debris Tank
Clean Primary Shut-off Valve
Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.
To clean:
1.
Open tank door. See “Drain Tank” on page 48.
2.
Spray valve housing inside vacuum tank with
high-pressure water.
3.
Store water pressure hose.
4.
Close tank door. See “Drain Tank” on
page 48.
To remove:
1.
Remove nuts and bolts (1).
2.
Remove cover (2).
3.
Remove ball (3).
4.
Clean ball and housing with high-pressure water.
5.
Replace ball and housing.
6.
Install cover and secure with nuts and bolts.