Debris tank, Mv800 operator’s manual – Ditch Witch MV800 User Manual

Page 89

Advertising
background image

Service - 88

MV800 Operator’s

Manual

As Needed

CMW

®

Debris Tank

Clean Primary Shut-off Valve

Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.

To clean:

1.

Open tank door. See “Drain Tank” on page 48.

2.

Spray valve housing inside vacuum tank with
high-pressure water.

3.

Store water pressure hose.

4.

Close tank door. See “Drain Tank” on
page 48.

To remove:

1.

Remove nuts and bolts (1).

2.

Remove cover (2).

3.

Remove ball (3).

4.

Clean ball and housing with high-pressure water.

5.

Replace ball and housing.

6.

Install cover and secure with nuts and bolts.

Advertising