Service - 154

RT120 Operator’s Manual

Service Precautions

Service Precautions

Welding

Cleaning

Changing Attachments

The RT120 T4i is programmed to operate with the original attachment configuration. If you change
attachments, contact your Ditch Witch dealer to make sure the electronic programming is updated. If you
change attachments without updating the electronic programming, your attachment may not function
correctly.

Read operator’s manual. Know how to use all controls before operating

machine. When you see this sign

on the machine or in the manual, read it and use

caution. Your safety is at stake.

To help avoid injury:

Perform all service with the engine off unless otherwise instructed.

Refer to engine manufacturer’s manual for engine maintenance instructions.

Lower unstowed attachments to ground, before servicing equipment,

NOTICE: Welding can damage electronics.

Disconnect battery at battery disconnect switch, if equipped, or disconnect battery cables before
welding to prevent damage to battery. Do not turn off battery disconnect switch with engine running
or alternator and other electronic devices may be damaged.

Connect welder ground clamp close to welding point and make sure no electronic components are in
the ground path.

Always disconnect the ECU ground connection from the frame, harness connections to the ECU,
and other electronic components prior to welding on machine or attachments.

NOTICE: When cleaning equipment, do not spray electrical components with water.