100 hour, Tractor, Rt120 operator’s manual – Ditch Witch RT120 User Manual
Page 176
Advertising
RT120 Operator’s Manual
Service - 175
100 Hour
100 Hour
Tractor
Change Engine Oil and Filter (Initial)
Change engine oil and filter at 100 hours if fuel
sulfur content is above 500 ppm (500 mg/kg).
See page 157 for more information about DEO
specifications.
To change:
1.
While oil is warm, remove drain plug (3).
Drain oil and replace plug.
2.
Remove filter (1) and replace with new filter
each time oil is changed. Add DEO at fill
neck (2).
Location
Task
Notes
TRACTOR
Change engine oil (Tier 3)
Initial; if using fuel with sulfur
content above 500 ppm (500
mg/kg)
Lube axle mounts
EPG
Lube driveshaft U-joints
EPG
Lube king pins
EPG
PLOW
Check plow shear mounts
Test plow connector pivots
1
3
2
t41om018w.eps