Service - 66

R150/R230/R300 Operator’s Manual

10 Hour

CMW

10 Hour

Power Unit

Check Hydraulic Hoses

Check hydraulic hoses for leaks every 10 hours.

Location

Task

Notes

Power Unit

Check hydraulic hoses

Inspect insulation

R150 only

Trencher

Lube trencher pivot

MPG

Lube trencher headshaft bearing

MPG

Check digging chain tension

MPG

Fluid or air pressure could pierce skin and cause injury or

death. Stay away.

NOTICE: Escaping pressurized fluid can cause injury or pierce skin and poison.

Before disconnecting a hydraulic line, turn engine off and operate all controls to relieve pressure.
Lower, block, or support any raised component with a hoist. Cover connection with heavy cloth and
loosen connector nut slightly to relieve residual pressure. Catch all fluid in a container.

Before using system, check that all connections are tight and all lines are undamaged.

Fluid leaks can be hard to detect. Use a piece of cardboard or wood, rather than hands, to search
for leaks.

Wear protective clothing, including gloves and eye protection.

If you are injured, seek immediate medical attention from a doctor familiar with this type of injury.