250 Hour
CMW
250 Hour
Power Unit
Change Hydraulic Fluid and Filter
Change hydraulic fluid and filter every 250 hours.
1.
Drain hydraulic fluid at drain (3).
2.
Replace plug.
3.
Change filter (shown).
4.
Add THF at fill neck (1, above) until level is at
halfway point on sight glass (2, above).
Location
Task
Notes
Power Unit
Change hydraulic fluid and filter
THF
Change fuel filter