100 hour, Power unit – Ditch Witch Zahn User Manual

Page 74

Advertising
background image

R150/R230/R300 Operator’s Manual

Service - 73

100 Hour

CMW

100 Hour

Power Unit

Change Engine Oil - R150

Change engine oil every 100.

1.

Move drain hose (1) to front of unit and drain
while oil is still warm.

2.

Replace plug.

3.

Add 1.6 qt (1.1 L) of GEO at fill neck (2).

Change Engine Oil and Filter - R230/
R300

Change engine oil and filter every 100 hours.

1.

Move drain hose (1) to front of unit and drain
while oil is still warm.

2.

Replace plug.

3.

Install new filter (3).

4.

Add 2 qt (1.9 L) of GEO at fill neck (2).

Location

Task

Notes

Power Unit

Change engine oil - R150

GEO

Change engine oil and filter - R230/R300

GEO

Change air filter

IMPORTANT: If operating in extremely dusty
conditions, change oil more frequently. Use oil
specified in temperature chart found in
“Recommended Lubricants/Service Key” on
page 62
.

IMPORTANT: If operating in extremely dusty
conditions, change oil more frequently. Use oil
specified in temperature chart found in
“Recommended Lubricants/Service Key” on
page 62
.

Advertising