Rt120q operator’s manual – Ditch Witch RT120 Q User Manual
Page 156
Advertising
RT120Q Operator’s Manual
Service - 155
10 Hour
Check Hydraulic Fluid Level
With frame level, check fluid at sight glass every
10 hours. Add THF at fill as necessary.
Clean dust from cap by blowing with low-pressure
air.
IMPORTANT:
•
Open cap slowly, tank may be under
pressure.
•
Do not open unless adding hydraulic fluid.
t37om018w.eps
Advertising