Rt120q operator’s manual – Ditch Witch RT120 Q User Manual

Page 157

Advertising
background image

Service - 156

RT120Q Operator’s Manual

10 Hour

Check Hydraulic Hoses

Check all hydraulic hoses every 10 hours.

Fluid or air pressure could pierce skin and cause injury or death. Stay

away.

To help avoid injury:

Before disconnecting a hydraulic line, turn engine off and operate all controls to relieve pressure.
Lower, block, or support any raised component with a hoist. Cover connection with heavy cloth and
loosen connector nut slightly to relieve residual pressure. Catch all fluid in a container.

Before using system, check that all connections are tight and all lines are undamaged.

Use a piece of cardboard or wood, rather than hands, to search for leaks.

Wear protective clothing, including gloves and eye protection.

If you are injured, seek immediate medical attention from a doctor familiar with this type of injury.

Advertising