Custom Lookup Extension Component Programming

Table 70. GetRemoteTCPPort Parameters

Parameter

Description

tcpPort

Integer variable that stores the return data.

Returns

The remote TCP port number of the RNI as an Integer.

SetRemoteTCPAddress Method

Applies to: Session Control Object
This method sets the remote TCP address of the RNI. For a downlink session, it

is the responsibility of the xDriver lookup extension to map the downlink lookup

key to the database, extract the TCP address from the database, and fill it into

the SCO using this method.
For an uplink session, the remote TCP address is filled in to the SCO

automatically by the Connection Broker.

Syntax

C++

STDMETHOD(SetRemoteTCPAddress)(BSTR tcpAddress)

Visual Basic Sub SetRemoteTCPAddress(ByVal tcpAddress As String)

Table 71. SetRemoteTCPAddress Parameters

Parameter

Description

tcpAddress

The remote TCP Address used to connect to the

RNI as a dotted decimal IP address, or as a hostname. If an IP

address is used, it must be entered in the form x.x.x.x, where x

represents an integer between 0 and 255.

Returns

Standard COM HRESULT describing the result of the call. Returns

LdvxLib.LdvxResult.E_ACCESSDENIED if the field is currently read-only.

Table 68 on page 178 lists each SCO_TCP field, along with when these fields

are read-only.

SetRemoteTCPPort Method

Applies to: Session Control Object

Advertising