POWER SUPPLY TESTING

Plug the trainer into a 120VAC outlet and switch to the “ON” position (the power switch should light). With a
digital voltmeter, measure the voltage outputs at the power blocks. The +12V should measure between 11.4
and 12.6 volts. The 5V supply should read between 4.75 and 5.25 volts. The –12V supply should read between
–11.4 and 12.6 volts.

Do not short the 15VAC output to ground.
Short the +12V, –12V and +5V supply to ground. They should turn off and recover when the short is removed.
If you have a 25

10 watt resistor, place it across the output terminal (2 watt resistor will work, but use it only

for a few seconds). The output of the 12V supply should not change more than 0.20 volts. Do the same on the
5V supply using a 10

5 watt resistor. Again, the output should not change more than 0.20 volts. In making

this test, the voltmeter leads should be clipped to the terminal directly and no to the load leads. This is to prevent
errors due to voltage drop from contact resistance of the load.
Check the variable voltage supplies in the same manner. Set the output voltage between 10-15 volts. Place
the 25

10 watt resistor across the output terminal. The voltage should stay within 0.20 volts of the no load

voltage.

TROUBLESHOOTING CHART

This chart lists the condition and possible causes of several malfunctions. If a particular part is mentioned as
a possible cause, check that part to see if it was installed correctly. Also, check it and the parts connected to it
for good solder connections. Note: The values given in this troubleshooting chart are an approximation.

PROBLEM

POSSIBLE CAUSE

Switch doesn’t light.

1. Check fuse and line cord.

Fuse blows when the unit is turned on.

1. Voltage supply shorted to GND.

Use resistance analysis

chart to find short.

No or low voltage at positive variable

1. Measure for an AC voltage of 18VAC at anode of D7 & D9.

output.

A. Transformer and/or secondary connection to PC

board defective

2. Measure for a DC voltage of 28VDC at pin 3 of U1 LM317.

A. Diodes D7, D9 in backwards or defective, check

capacitor C1.

3. Set the voltage for minimum 1.25VDC and measure pin 2

of U1.

A. Voltage adjusts only from 7.8 - 9.8V R1 open or

defective.

B. Voltage 27V, check VR1 connections.

No or low voltage at positive variable

1. Check that capacitor C1 1000

µ

F is inserted in the correct

output with load.

polarity.

2. Check ripple on pin 3 of U1. 8VP-P Max.

A. Capacitor C1, and/or diodes D7, D9 defective.

Advertising