ED, EG Rev. 2 - Operating Instructions

GB

Signal individual protection device

HAND PROTECTION
(gloves for protection against chemical, ther-
mal and mechanical risks).

5. TRANSPORTATION AND HANDLING
The product is packed to maintain the content intact.
During transportation avoid to stack excessive wei-
ghts. Ensure that during the transportation the
packed cannot move.
The transport vehicles must comply, for the weight
and dimensions, with the chosen product.

5.1 Handling
Handle with care, the packages must not receive
impacts.
Avoid to impact onto the package materials that
could damage the pump.
If the weight exceeds 25 Kg the package must be
handled by two person at the same time.

6 INSTALLATION

6.1 Dimensions
For the dimensions of the device see technical cata-
logue.

6.2 Ambient requirements and installation site

dimensions

The customer has to prepare the installation site in
order to guarantee the right installation and in order to
fulfill the device requirements (electrical supply,
etc...).
It's Absolutely forbidden to install the machine in an
environment with potentially explosive atmosphere.

6.3 Unpacking

Inspect the device in order to check any
damages which may have occurred during
transportation.

Package material, once removed, must be discar-
ded/recycled according to local laws of the destina-
tion country.

6.4. Pipes
The internal diameter of the delivery pipe must never
be smaller than the diameter of the pump connection
port:
G 1

1

/

2

(DN 40) for ED, EDV, EGN;

G 2

(DN 50) for EGT, EGF;

ATTENTION: The pump must be lifted and
transported using the handle fitted for this
purpose and not pulled by the electrical power
cable.
Place the pump, with vertical axis, at the bottom of
the pit or at the site of installation.

6.5. Stationary installation

Installation fit a check valve against back flow in the
delivery pipe ball valve (swing valve for EGN).
Provide for the possibility of removing the pump
without having to drain the entire system (if
necessary, fit a gate valve and a union coupling).
With the pump in the resting position secure the
delivery pipe to a rest, suitable for its length and
weight.
If slime deposits are expected to form at the bottom
of the installation pit, a support must be provided to
keep the pump raised.

6.6. Transportable installation

To avoid early deterioration of the pump when used
in stagnant water or in rivers, mount on a flat surface
raised from the ground so that sand or grit is not lif-
ted.
When a plastic delivery pipe or flexible hose is used,
a rope is required for lowering, securing and lifting
the pump.
A safety rope or chain of non-perishable material
should always be used to secure the pump.

i

min 550 x 550

3.93.037/3

h

max

h

min

mm

h

min

h

max

h

min

h

max

205

220

220

245

265

265

410

425

425

450

470

470

GQR 10-10

GQR 10-12

GQR 10-14

GQR 10-16

GQR 10-18

GQR 10-20

mm

h

min

h

max

mm

mm

mm

3.93.004/1

GQR

GQS, GQV 50-9

GQS, GQV 50-10

515

530

260

275

GQS, GQV 50-11

555

300

GQS, GQV 50-13

575

320

320 575

GQS, GQV 50-15

GMC 50...

GMV 50...

500

500

180

180

GMC 50-65..

505

185

GMC 50-65..

505

185

mm

h

min

h

max

225
240
240
265
285

315
330
330
355
375

h

max

h

min

min 300 x 250

3.93.037/3

GQRM 10-10 GF
GQRM 10-12 GF
GQRM 10-14 GF
GQRM 10-16 GF
GQRM 10-18 GF

GXV(M) 40-7
GXV
(M) 40-8

508
533

248
273

GXV(M) 40-9 533 273

GXC(M) 40-10
GXC
(M) 40-13

508
533

248
273

M

1

4.67.380

h

max

h

min

h

max

h

min

min 550 x 550

3.93.037/3

h

max

h

min

mm

h

min

h

max

h

min

h

max

205

220

220

245

265

265

410

425

425

450

470

470

EGN 4

EGN 5

EGN 7

EGN 9

EGN 11

EGN 15

mm

mm

mm

3.93.004/1

EGN

EGT, EGF 5

EGT, EGF 7

EGT, EGF 9

EGT, EGF 11

EGT, EGF 15

515

530

260

275

555

300

575

320

320 575

mm

h

min

h

max

225
240
240
265
285

315
330
330
355
375

h

max

h

min

min 300 x 250

3.93.037/3

GQRM 10-10 GF
GQRM 10-12 GF
GQRM 10-14 GF
GQRM 10-16 GF
GQRM 10-18 GF

EDV 5

EDV 7

EDV 9

ED 5

ED 9

508
533

248
273

533 273

508
533

248
273

M

1

4.67.380

h

max

h

min

h

max

h

min

On

Off

TYPE

TYPE

TYPE

TYPE

IST ED_ED_04_2015:MXS 11_03con gall 14/04/15 17:45 Pagina 11

Advertising
This manual is related to the following products: