6.8.

LIGHTNING GROUND ROD:

WARNING: Prior to installing, ensure that any underground electrical

conductors, natural gas lines, water/drain lines, and/or other interferences
are located and will not hinder the installation.

6.8.1.

Since aluminum can conduct electricity, the MLGRK (LIGHTNING GROUND
ROD KIT) provides the components needed to ground a ramp system.

6.8.2.

Drive the grounding rod straight into the ground as close as possible (within
1 1/2 feet maximum) to one of the support tubes leaving approximately 2"
exposed.

6.8.3.

Install the brace band around support tube. Place the #8 copper wire under
the brace band on the corner as shown (FIG. 6.22)

6.8.4.

Install the 5/16

″-18 carriage bolt nut and flat washer and tighten so that wire

is in good contact with support tube.

6.8.5.

Install 5/8

″ grounding rod clamp to grounding rod. Place #8 wire between

clamp and rod then tighten the clamp.