Site selection and preparation, Fireplace installation – Dimplex DF3215NH User Manual

Page 7

Advertising
background image

7

!

NOTE: A 15 Amp, 120 volt circuit is required. A dedicated circuit

is preferred but not essential in all cases. A dedicated circuit will

be required if, after installation, the circuit breaker trips or fuse

blows on a regular basis when the heater is operating. Additional

appliances on the same circuit may exceed the current rating of the

circuit breaker.

WARNING: Ensure the power cord is not installed so that it is

pinched or against a sharp edge and ensure that the power cord is

stored or secured to avoid tripping or snagging to reduce the risk of

fire, electric shock or injury to persons.

Construction and electrical outlet wiring must comply with local

building codes and other applicable regulations to reduce the risk

of fire, electric shock and injury to persons. Do not attempt to wire

your own new outlets or circuits. To reduce the risk of fire, electric

shock or injury to persons, always use a licensed electrician.

Site Selection And Preparation

This section provides instructions for selecting a location and preparing

the site to install the fireplace into your Dimplex mantel surround.
1. Select a suitable location that is not susceptible to moisture and is

away from drapes, furniture and high traffic.

2. For ease of electrical hook up you may wish to locate the fireplace

near an existing outlet (refer to NOTE 1).

3. Store the fireplace in a safe dry and dust free location.

!

NOTE:

The dimensions of the fireplace are 36 ½ inches (927 mm)

wide X 31 ¾ inches (806 mm) high X 13 inches (330 mm) deep.

The viewing area is 32 inches (813 mm) wide and 28 ¼ (715 mm)

high. The fireplace does not require any additional venting

.

Fireplace Installation

1. Install the Bi-fold doors to the fireplace.

!

IMPORTANT: Bi-fold doors MUST be installed to the firebox prior

to installing firebox to mantel.

Advertising