Serial Communication (SCOM) Interface

Communication Interface

IND100084-12

“BRT” - User Brightness Control

This command is sent to the unit to command the backlight brightness control setting.The brightness value shall be sent

as one byte in the DATA field. A setting of 0x00 will indicate off. A setting of 0xFF (255 in value) will indicate maximum

brightness. Intermediate values will control brightness over the range from minimum to maximum luminance.

LEN = one data byte.

After any power cycle the BRT will be set to 100%.

If the data checksum is valid and the brightness was set, the unit will reply to this command with an ACK attention code.

The DATA field in the reply shall indicate the resulting brightness control setting. If an invalid checksum was received

and the message was not Broadcast and RS-485, the unit will reply with an NAK attention code. The DATA field in the

reply will indicate the current brightness control setting.

Example:

If BRT is 100%, the user can adjust the brightness from 0-100%. If the BRT is set to 60%, the visual brightness is set to

60%. The user can adjust the brightness from 0-100% within the 60% set by BRT. If the user sets the potensiometer to

half, the visual brightness will be 30% (half of 60%). If BRT is set back to 100%, the visual brightness will be 50% (half

of 100%).

Command to set 60% Brightness:

0x07

0xFF

0x42

0x52

0x54

0x01

0x10

0x99

0x66

Acknowledge was set to 60% Brightness:

0x06

0xFF

0x42

0x52

0x54

0x01

0x11

0x99

0x66

Negative Acknowledge 40% Brightness:

0x15

0xFF

0x42

0x52

0x54

0x01

0x02

0x66

0x99

“BZZ” - Buzzer Control

This command is sent to the unit to control buzzer on/off if there is a buzzer present. LEN = one data byte.

0x00

Turn the buzzer off

0xFF

Turn the buzzer on

If the data checksum is valid, the unit will reply to this command with an ACK attention code. The DATA field will indicate

the buzzer state. If an invalid data checksum was received and the message was not broadcast and RS-485, the unit

will reply with a NAK attention code and the current control setting.

Example:

Command to set Buzzer Enable: 0xFF

0x07

0xFF

0x42

0x5A

0x5A

0x01

0x02

0xFF

0x00

Acknowledge Buzzer status was set to Enable: 0xFF

0x06

0xFF

0x42

0x5A

0x5A

0x01

0x03

0xFF

0x00