Hatteland Display 19 inch - JH 19T14 MMC User Manual

Page 24

Advertising
background image

24

Serial Communication (SCOM) Interface

Communication Interface

IND100084-12

MCC Command

Syntax and Functionality

ACK Details and Values

Command Availability Query

Syntax : 07 FF 4D 43 43 03 23

C4

xx yy

zz

Function Examples:
Example "C4" : 07 FF 4D 43 43 03 23

C4

43 34

C4

Where

xx

= "0" to "F"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Example on Response:

"0" = Not available

"1" = Available

Auto Calibration

Note:

Start auto-calibration of gain of

the RGB amplifier.

Send Only : 07 FF 4D 43 43 01 25

C5

3A

Available response status:

"0" = Fail

"1" = Successful

Soft Power On/Off

Syntax : 07 FF 4D 43 43 02 24

C8

xx

zz

Function Examples:
Example "1" : 07 FF 4D 43 43 02 24

C8

31

06

Query "?" : 07 FF 4D 43 43 02 24

C8

3F

FB

Where

xx

= "0" to "1"

Where

zz

= Calculated Checksum

Available functions:

"0" = Soft Power Off

"1" = Soft Power On

Query EVX Firmware Version

Send Only : 07 FF 4D 43 43 02 24

CB

30

04

Available response status:

Version "VV.YY.ZZ?"

VV = V0 or E0

V0 = Release version

E0 = Engineering Sample

YY = Version Number

ZZ = Customer Number

? = For E0 version (A-Z)

Test Pattern

Syntax : 07 FF 4D 43 43 02 24

CD

xx

zz

Function Examples:
Example "1" : 07 FF 4D 43 43 02 24

CD

31

01

Where

xx

= "0" to "1"

Where

zz

= Calculated Checksum

Available functions:

"0" = Normal Display

"1" = Display built-in Test Pattern

Reset Factory Default

Send Only : 07 FF 4D 43 43 01 25

CE

31

Available response status:

"0" = fail

"1" = successful

Save User Default

Send Only : 07 FF 4D 43 43 01 25

D7

28

Available response status:

"1" = successful

Load User Default

Send Only : 07 FF 4D 43 43 01 25

D8

27

Available response status:

"1" = successful

Wide Screen Mode Selection

Syntax : 07 FF 4D 43 43 02 24

D9

xx

zz

Function Examples:
Example "2" : 07 FF 4D 43 43 02 24

D9

32

F4

Query "?" : 07 FF 4D 43 43 02 24

D9

3F

E7

Reset "R" : 07 FF 4D 43 43 02 24

D9

52

D4

Reset "r" : 07 FF 4D 43 43 02 24

D9

72

B4

Where

xx

= "1" to "2"

Where

zz

= Calculated Checksum

Available functions:

"1" = 1280x768

"2" = 1366x768

If wrong instruction: "?"

Setup DDC

Send Only : 07 FF 4D 43 43 01 25

DC

23

Available response status:

"1" = successful

Setup Serial Mode

Syntax : 07 FF 4D 43 43 03 24

DB

xx yy

zz

Function Examples:
Example "A2" : 07 FF 4D 43 43 03 24

DB

41 32

B1

Query "?" : 07 FF 4D 43 43 02 24

DB

3F

E5

Where

xx

= "0" to "F"

Where

yy

= "1" to "3"

Where

zz

= Calculated Checksum

Available functions (

xx

):

xx

= Serial Address 0-15 number

Available functions (

yy

):

"1" - RS-232

"2" - 2-wire RS-485

"3" - 4-wire RS-485 / RS-422

Swap Main & PIP/PBP Source

Note:

Not available on STD units.

Send Only : 07 FF 4D 43 43 01 25

E3

1C

Available response status:

"0" = Fail

"1" = Successful

Read Temperature Sensor

Send Only : 07 FF 4D 43 43 01 25

E4

1B

Available response status:

"xx" = where xx is 2-digit

temperature value in Celcius

Degrees

Advertising