Introduction – Hatteland Display 19 inch - JH 19T14 MMC User Manual

Page 5

Advertising
background image

5

IND100084-11

Introduction

This document defines the electrical interface, serial data format, and communication protocol of the Serial

Communication Control Interface. The purpose of this interface is to enable a computer application to control one or

more units. Units refer to either displays or panel computers.

Serial Interface Configuration

The serial interface can have different configurations, selected by the OSD menu. The configurations are defined as

follows:

RS-232

One computer controls one unit, no individual address

4-wire RS-485/RS-422

One computer controls max 16 units, each with individual address.

2-wire RS-485

One computer controls max 16 units, each with individual address.

Cables

A cable with an overall shield terminated at the back shell should be used.

Electrical Interface

Electrical signals shall conform to RS-485, RS-422 or RS-232. Only Receive Data, Transmit Data, and Signal Ground

are used. The same conditions apply for both 4-wire and 2-wire, and will just be referred to as RS-485 in this document.

Hardware handshake is only supported by loopback handshake for RS-232.

- Display (Maritime Multi Display - MMD) based units with Multifunction Cable (VSD100692 series):

• SCOM RS-232

: 1 x 9P DSUB (female) COM1 RS232

• SCOM RS-422/485 : Multifunction Cable customized/optional on request

- Display (Industrial Standard Display - STD) based units with Multifunction Cable (VSD100692 series):

• SCOM RS-232

: 1 x 9P DSUB (female) COM1 RS232

• SCOM RS-422/485 : Multifunction Cable customized/optional on request

- Panel Computer (Maritime Multi Computer - MMC) based units are by factory default manufactured with:

• COM RS-232 : Internal Virtual COM

3

(No pin-out assignments needed, handled by OS/Driver)

Internal Virtual COM

x

(VCOM), where

x

is OS/configuration dependent. This Virtual COM port enables you to

send commands TO the same unit that you are sending FROM, which means there is no need to differentiate

between local control or remote control for communicating through physical ports such as RS-232, RS-485 /

RS-422 towards other units located externally.

Communication Interface