Hatteland Display 19 inch - JH 19T14 MMC User Manual

Page 16

Advertising
background image

16

Serial Communication (SCOM) Interface

Communication Interface

IND100084-12

“TMP” - Temperature Sensor Query

The unit features a sensor that measures the temperature inside. The unit will reply to this command with an ASCII

string indication the temperature in Celcius degree (°C).

0x52

"R" = Read current temperature

0x48

"H" = Read Temperature Histogram

The histogram is a table for temperature -55 to 125 °C and be divided to 12 parts. The temperature range for each part

is 16 °C and each part use two bytes.

Example:

Command Read Current Temperature “R”:

0x07

0xFF

0x54

0x4D

0x50

0x01

0x07

0x52

0xAD

“TYP” - Type/Model Number Query

This query is sent to the unit in order to identify the unit type by its model number / part number. No data shall be sent

with this query.

The unit will reply to this command with an ACK attention code. The DATA field will be set to an text string to indicate

the specified Type/Model Number, e.g: “JH23T01MMD-A1”.

Example:

Command to retrieve Type/Model Number

0x07

0xFF

0x54

0x59

0x50

0x00

0xFC

Acknowledge Type/Model Number “JH20T03”:

0x06 0xFF 0x54 0x59 0x50 0x07 0x1A 0x4A 0x48 0x32 0x30 0x54 0x30 0x33 0x54