Serial Communication (SCOM) Interface

Communication Interface

IND100084-12

"DL?" - Query available ECDIS packages

This command is ask the unit to return there are how many packets in ECDIS table available for download. Each

calibration mode is separate. If we at ‘Calibration VGA’ mode, we will get the available packets number at VGA table,

and also on ‘Calibration DVI’. But there is no available packet at ‘No Calibration’.

Packets = Size of Table / 32 bytes per packet

Example:

Command to read package #3:

0x07 0xFF 0x44 0x4C 0x3F 0x00 0x2A

Acknowledge: DL? 3 available packets:

0x06 0xFF 0x44 0x4C 0x3F 0x01 0x2A 0x03 0xFC

“DST” - Display State

This command is sent to the unit to control the unit on/off or query the on/off state of the unit.

LEN = one data byte. NOTE: This command is available from version SW100066-1G09 and upwards.

0x00

Turn the unit off

0xFF

Turn the unit on

0x3F

“?” - Query the state of the unit. The returned DATA field will indicate the state.

0x00 = Unit is off. 0xFF = Unit is on.

If the data checksum is valid, the unit will reply to this command with an ACK attention code. The DATA field will indicate

the unit sate. If an invalid data checksum was received and the message was not broadcast and RS-485, the unit will

reply with a NAK attention code and the current state.

Example:

Query Display State:

0x07

0xFF

0x44

0x53

0x54

0x01

0x0D

0x3F

0xC0

Acknowledge Display state, unit is on:

0x06

0xFF

0x44

0x53

0x54

0x01

0x0E

0xFF

0x00

Acknowledge Display state, unit is off:

0x06

0xFF

0x44

0x53

0x54

0x01

0x0E

0x00

0xFF