Communication Interface

IND100084-6

Installation in unit

Connectorization

The remote control interface communicates with external equipment via the appropriate connector(s). Some units

may need a custom cable to operate properly. Please review the “Physical Connections” and the “Pin Out

Assignments” chapter of the units user manual to determine the correct connectorization and installation of cables

and connectors before proceeding into this chapter on the following pages.

For systems with more than one unit, the units are connected together through the unoccupied D-SUB (if available).

It is regardless which one is used, but normally COM-1 is connected to another unit, and COM-2 is connected to the

external PC.

Address

A unit’s address is set by a 5-bit dipswitch (red) on the backside of the unit (own page in this manual describes its

location). Only bits 1-4 are currently in use. The position of bit 5 has no effect.Address is adjusted according to the

following table:

Address

Bit 1

Bit 2

Bit 3

Bit 4

0

Off

Off

Off

Off

1

On

Off

Off

Off

2

Off

On

Off

Off

3

On

On

Off

Off

4

Off

Off

On

Off

5

On

Off

On

Off

6

Off

On

On

Off

7

On

On

On

Off

8

Off

Off

Off

On

9

On

Off

Off

On

10

Off

On

Off

On

11

On

On

Off

On

12

Off

Off

On

On

13

On

Off

On

On

14

Off

On

On

On

15

On

On

On

On

Selecting communication mode:

Communication mode (U5)

Duplex (U8)

RS-232

RS232

-

RS-485

Full duplex

RS422/485

Full (on)

Half duplex

Half (off)

These settings are normally carried out by manufacturer before delivery.