11

Hitec Brushless Servo PC Programming Interface

DPC-10

DPC-10 Software Operating Manual

Resetting EPAs

Fail Safe Position

By choosing to use the Fail Safe function you will need
to set a preprogrammed travel point that the servo
will travel to in the event the servo loses signal from
the receiver.

WARNING – Program the Fail Safe point after
setting the end and center points otherwise it will
change when you make those settings.

To set the Fail Safe point first, click on the “Fail Safe”
under the Program section.

WARNING

WARNING

Next move your servo to the desired position by using
the Manual positioning section as shown. You can
use any of the preset points or you can move it in one
of three other ways, either in 1µs steps by clicking
on the arrows “< - >”, in 50µs steps by clicking on the
white space of the adjustment bar or with the slide in
the adjustment bar.

Once you have your desired Fail Safe position, click on
the FS-Position button Fail Safe Test as seen in the
illustration.