User manual and installer guide, Vision pro – Lumagen VisionPro User Manual

Page 24

Advertising
background image

Vision Pro

User Manual and Installer Guide

© 2003 Lumagen, Inc.

21

Rev 1.13

Lock the Configuration

The configuration can be locked to prevent unintended changes. When locked, the input
selection keys function normally, but setup parameters are fixed. The command format is:

MENU

MISC

LOCK

(

UNLOCKED

,

LOCKED)

,

OK

The following command can unlock the configuration memories without being able to
see the screen.

MENU 0 9 1 5

Same as

MENU

MISC

LOCK

UNLOCKED,

OK

Initial Power State

When power is first connected to the unit, it can be set to turn on (

ON)

, or it can start in

standby mode (

STBY)

. Note,

ON

and

STBY

commands are not affected. The command

format is:

MENU

MISC

POWR

AUTO

(

ON

,

STBY)

,

OK

Power-On Message

A user generated text message can be displayed when power is applied, or the

ON

key is

pressed. The and arrows select which character to change. The and arrows change
the selected character. The command format is:

MENU

MISC

POWR

MSG

[ , , , ],

OK

Test Patterns

Warning:

Test patterns can cause screen burn-in. Do not leave

test patterns displayed for more than a few seconds.

There are several test patterns available. The and arrows select the test pattern. The
intensity can be adjusted from 10 to 100 IRE, in 10 IRE steps, using the and arrows.
The command format is:

MENU

MISC

TPAT

OK

, [ , , , ]

Genlock

Genlock puts the input and output frames in “lock-step.” When enabled, genlock makes
sure all input frames arrive at the output a fixed time later. In other words, no frames are
dropped and none are repeated. Very few people can notice any difference whether
Genlock is enabled or disabled (default). Note: Not all displays are capable of
synchronizing to the slightly different timing Genlock produces. If the image is not
stable, or not visible, disable Genlock. To enable Genlock:

MENU 0 9 8 1

Toggle genlock. Default = off. (can be saved)

To check the status of Genlock:

MENU 0 9 8 2

Genlock status (off, locked, unlocked)