User manual and installer guide, Vision pro, Saving the configuration – Lumagen VisionPro User Manual

Page 26

Advertising
background image

Vision Pro

User Manual and Installer Guide

© 2003 Lumagen, Inc.

23

Rev 1.13

Saving the Configuration

Note:

Power must be maintained during save and undo commands. If power is interrupted, the

command may fail to complete. If this occurs, the unit will revert to factory defaults.

Save

Note:

If a save command is not executed, any changes will be lost when the

unit is put into standby power mode, or if power is interrupted.

Permanently save the current configuration. Note that, once saved, the configuration is
retained even if the unit is disconnected from power. The command format is:

MENU

SAVE

SAVE

,

OK

,

OK

Implicit: Configuration from previous save is retained to allow one-level of save-undo.

Save Undo

Revert to the configuration over-written by the last save. Repeating the save undo
command toggles between the last two saved configurations.

Hint:

To discard unsaved changes, temporarily enter standby mode.

The command format is:

MENU

SAVE

UNDO

,

OK

,

OK

Revert To Factory Settings

Sets all parameters to factory defaults, but does not save them into nonvolatile memory.

MENU

,

0

,

9

,

9

,

9

or

MENU

SAVE

FCTRY

,

OK

It is possible to reset only the current output resolution to default settings, while leaving
input setting unchanged. The command is:

MENU 0 9 9 8

Reset current output (only) to defaults for current

resolution

Advertising