Audible feedback, Troubleshooting guide – Mighty Mule MM600ET-PRO User Manual

Page 36

Advertising
background image

Audible Feedback

Symptom

Diagnosis

Check:

1 short beep upon
activation

Blown Fuse
Low or Bad Battery
Loose Battery Connection

• Fuses - control board and battery harness cable
• Battery Under Load
• Battery Harness Connections

1 short beep upon
power up

Circuit Board Powered
Up & Ready

• Normal Operation

Continuous
Uninterrupted Alarm

Circuit Board Senses an
Obstruction

• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices
• Rev Counter

1 beep with 10 seconds
off

Low Battery Condition

• Fuses - control board and battery harness cable
• Battery Harness Connections
• Battery Under Load

1 beep then 2 beeps with
2 seconds off

Master Motor Terminals
Shorted

• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board

1 beep with 2 seconds
off

Master Arm Limit Switch
Error

• Connections to Master Inputs
• Master Arm Power Cable
• Master Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC across each terminal.

3 beeps with 2 seconds
off

Master Arm Rev Counter
Error

• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter

33

Troubleshooting Guide

If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.

Additional information can be found online 24 hours 7 days a week at the

GTO Tech Wizard

(support.gtoinc.com/Support/TroubleShooter.aspx)