Visual feedback – Mighty Mule MM600ET-PRO User Manual

Page 37

Advertising
background image

34

Visual Feedback

Symptom

Diagnosis

Check:

Status (clear)
1 blink

Cycle Terminal
Shorted

Disconnect the push button, keypad, intercom keypad, or any other
accessory wired to this terminal. Try the remote. If the remote works, then
the problem is the accessory.

Status (clear)
2 blinks

Safety Terminal
Shorted

Disconnect the loop detector, photo beam, or any other accessory wired
to this terminal. Try the remote. If the remote works, the problem is the
accessory.

Status (clear)
3 blinks

Exit Terminal
Shorted

Disconnect exit wand, loop detector, photo beam, Knox box, or any other
accessory wired to this terminal. Try remote. If the remote works, the
problem is the accessory.

Status (clear)
4 blinks

Shadow Terminal
Shorted

Disconnect the loop detector, photo beam, or any other accessory wired to
this terminal. Try remote. If the remote works, the problem is the accessory.

Status (clear)
5 blinks

Close Edge Terminal
Shorted

Disconnect the edge sensor, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.

Status (clear)
6 blink

Open Edge Terminal
Shorted

Disconnect edge sensor, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.

RF (yellow) Flickers

Receiving 318 MHz
RF

Normal operation when remote or wireless keypad is used.

RF (yellow) OFF

No 318 MHz RF
Received

• Battery in Remote
• Program Remote
• Antenna Receiver Connections
• Antenna Receiver

Power (green) ON

AC or Solar Power
Present

Normal Operation

Power (green) OFF

No AC or Solar
Power

Transformer:
• Breaker or GFI
• Power at AC outlet.
• Output of Transformer.
• Voltage on wire at 18 VAC Input

Solar:
• Solar Panel Wires Reversed
• Weather
• Solar Panel Placement
• Output of Solar Panel
• Voltage on wire at Solar Input

Charge (red) ON

Fast Charging Mode

Battery Voltage should be increasing but must be less than 15 VDC when

connected to the circuit board

Charge (red) Fast
Blinking

Soak Charging Mode Battery Voltage should be ~14.1 VDC when connected to the circuit board

Charge (red) Slow
Blinking

Float Charge

Battery Voltage should be ~13.8 VDC when connected to the circuit board

Charge (red) OFF

Battery Not Being
Charged

• AC power
• Transformer
• Solar Panel
• Charging Circuit

Advertising