5 input and output settings – Dolby Laboratories P/N 91659 User Manual

Page 27

Advertising
background image

DolbyRemote Installation and Operation

Dolby Digital Parameters

4-11

4.5

Input and Output Settings

Figure 4-6 Input/Output Tab

4.5.1 Input

Lock Status
Lock Status
shows whether the input channels for the current coding mode have
been detected and locked by the encoder.

Sample Rate
Sample Rate
shows the sample rate of the digital input channels.

Integrity
Integrity
shows the data integrity of the digital input channels.

Format
Format
is a control parameter that allows you to choose the format of the data
received from the input source. Available Input Format selections are:

PCM: Dolby Digital encoding will be enabled. When analog is selected as the
DP567 input source, the input format must always be PCM.

Pre-encoded: Pass-through mode will be enabled. Pre-encoded bitstreams
move through the unit, unmodified, to the output.