INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,

MODELS RG24-5, SX-34GC, SX-55GC

MANUAL 1195732 REV0 (11/22/2011) 10 HEAVY DUTY STEAM

PLUMBING CONNECTIONS

(Continued)

COLD WATER CONDENSER

The steamer is equipped with a cold water condenser in the rear of the cooking chamber which

helps to condense the steam prior to discharge into drain. The steamer freely vents itself by

the negative pressure created by the condensate water drainage. This negative pressure

prevents steam leakage around the door gasket and helps draw the steam through the cooking

compartment. Steam leakage at the door may indicate a plugged or improperly installed drain.

WATER CONDITIONING

It is important that the water supply connected to this steamer be softened to no more than 2.0

grains of hardness and have a pH of 6 to 7.5. This degree of hardness can be easily obtained

with the use of a properly maintained water softener. The use of a water meter will determine

the water consumption and when the water softener needs regeneration or recharging. Failure

to comply with these water condition standards may void the warranty.

Untreated water contains scale producing minerals which can precipitate onto the surfaces in

the boiler. Due to the temperatures in the boiler, the minerals can bake onto the surfaces and

components. This can result in early component failure and reduced product life. Water level

probes become coated with scale. Scale will bridge across the probe insulator from the metal

extension which senses the water level in the boiler shell. Once this scale becomes wet, the

water level control is unable to maintain the proper water level in the boiler.

STRAINERS and FILTERS will NOT remove minerals from the water.