6.0 DELIMING PROCEDURE (For units equipped with this feature)

WARNING: Read and follow instructions on the CLR bottle. Use

plastic or rubber gloves to avoid skin contact. If CLR comes in

contact with skin, rinse with clean water.

1. Drain steam generator by setting power switch to “OFF”, set cooking timer to 0.

2. Turn power switch to DELIME.

3. Unscrew brass deliming plug on right side of steamer. Insert hose in hole of port. Pour 20

ounces of solution into generator slowly to avoid spillage. Remove hose. Screw deliming

plug back so it seals tightly. Turn power switch to on. (If there is no deliming plug on the

side of the steamer, check with your local service agency for proper deliming instructions of

your unit.)

4. Allow steamer to remain in ready cycle for ½ hour, then turn power switch “OFF” and allow

generator to drain.

5. Flush cycle. Turn power switch to “ON”. When ready light comes on, switch to “OFF” to

flush generator. Repeat this step three times to completely flush generator.

6. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean water.

Dry with a soft cloth.

LEAVE COMPARTMENT DOOR OPEN WHEN NOT IN USE.

The steamer is now ready for use. Turn off for overnight shutdown.