INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,

MODELS RG24-5, SX-34GC, SX-55GC

MANUAL 1195732 REV0 (11/22/2011) 9 HEAVY DUTY STEAM

ELECTRICAL CONNECTION

WARNING: Do not connect the kettle to the electrical supply until

after the gas connection has been made.

120 VAC-60 Hz-Single Phase

Units with this electrical rating are factory supplied with a three-wire cord and three-prong plug

which fits any standard 120V, three-prong grounded receptacle. A separate 15 amp supply is

needed for each unit.

PLUMBING CONNECTIONS

WARNING: Plumbing connections must comply with applicable

sanitary, safety and plumbing codes.

Two water lines are provided, one for each compartment. Connect water supply line to the 3/8"

copper tube in at the rear of the steamer. The 3/8" copper tube supplies water to both the

generator tank and to condense live steam entering the drain line.

DRAIN CONNECTIONS (FIGURE 2)

FIGURE 2

The drain connection must be 1" IPS

vertically down, preferably with one elbow

only, and maximum length of 6 feet, piped

to an open air gap type drain.

CAUTION: In order

to avoid any back

pressure in the

steamer, do not

connect solidly to

any drain connection.