Installation – Southbend NODR14: Floor Model Rinse Station User Manual

Page 11

Advertising
background image

NOD14: Floor Model High Efficiency Gas Pasta Cooker

INSTALLATION

L20-393, rev.1 (08/14)

7

WARNING

Ensure that your ventilation system does not cause a down draft at the appliance’s flue

opening. A down draft will not allow the appliance to exhaust properly and will cause

overheating, which may cause permanent damage. Damage caused by down drafts will not

be covered by the warranty. NEVER allow anything to obstruct the flow of combustion air or

ventilation air entering or exiting the appliance. NEVER place anything on top of the flue

exhaust area, or block the flue in any way. Never place a hood grease condensating drip

pan over the flue opening.

WARNING

NEVER connect the ventilation blower or hood directly to the flue of this appliance. The

resulting increased flow of air through the combustion system will cause improper

operation, poor temperature recovery, poor ignition and could extinguish the pilot.
















1.7. INSPECTION
Before you begin filling and adjusting the appliance, perform the following visual checks:

 After the appliance is in its permanent location, check the levelness. Any additional leveling that is necessary

can be performed as previously described.

 Ensure that the temperature probe (2), and high temperature limit sensing bulb (1) is in place and secure.

Check the high limit bulb mounting wing nut(s) (3) to ensure that they are tight.

 Review the installation portion of this manual and ensure that all steps have been followed and executed

properly.































Advertising
This manual is related to the following products: