Troubleshooting – Southbend NODR14: Floor Model Rinse Station User Manual

Page 25

Advertising
background image

NOD14: Floor Model High Efficiency Gas Pasta Cooker

TROUBLESHOOTING

L20-393, rev.1 (08/14)

21

Problem

Probable Causes

Corrective Actions

Controller does not
activate.

No power to appliance.

Check power cord and main
building power supply.

Circuit Breaker tripped.

Reset circuit breaker.

I/0 button not pressed On.

Press I/0 button to to turn on
controller.

Controller not turned on.

Turn on controller.

Power Cord loose or not connected. Connect power cord.

Controller displays
that it is heating but
water will not heat.

High temperature limit(s) has tripped

Allow appliance to cool and reset
High temperature limit(s).

4.4. TROUBLESHOOTING

CHART

4.5. CONTROLLER WARNING DISPLAYS
If your appliance is equipped with a temperature controller it may display the following warnings on its
display.



















Display Problem

Action

Water temperature

is low.

Wait for appliance to heat up.

Incorrect probe

reading.

Contact Authorized Service Company.

Water level is low.

Turn off appliance. Allow ample time for appliance to
cool before filling with water and turning on.

Incorrect probe
reading.

Contact Authorized Service Company.

Drain valve is open

while controller is
on.

Turn off appliance. Close drain valve before turning
appliance back on.

Advertising