Step 9:

Function Test

The function test may be performed with cartridges loaded in the CEW.

To perform a function test, follow these steps:

1

Point the CEW in a safe direction.

2

Place the top of the X2 CEW in the palm of your secondary hand so you can grip the top
rail and your thumb can reach the ARC switch, while the remainder of your secondary
hand and fingers are away from the front of the CEW.

3

Shift the safety switch to the up (ARMED) position. Keep all fingers away from the
trigger and keep the CEW pointed in a safe direction. While performing a function test,
DO NOT touch the trigger at any time.

4

Use your thumb to press the ARC switch.

5

Look at the CID display and verify the following:

No critical or major fault icons display on the upper-right corner of the CID.

The cartridge information matches the cartridges inserted in the X2 firing bays.

The battery icon displays a 20 percent or greater capacity.

If any of the above verifications fail, return the unit to your TASER technician for service.

WARNING

Use the ARC switch, not the trigger, to perform a function test.

Pressing the trigger will deploy the cartridge(s).