Specifications – Test Products International 460 User Manual

Page 7

Advertising
background image

o

A254 - For measuring low current in milliamps

o

A256 - Up to 400 AC/DC amps

o

A296 - Up to 1000 AC/DC amps

Specifications

Display:

Size

76mm X 76mm (3" X 3")

Pixels

240 X 240 pixels

LCD type

STN Normally Gray or Black

Back Light

CCFL

Memory:

Waveform Screens

(2)

Setup

User setup (1)

Power:

External

Power Adapter (5.5V / 2A)

Internal Battery

Ni-MH 1.2V X 4

Battery Operating Time

More than 2.5 hours with bright backlight

Charging Time

10 hours (in power off condition)

SCOPE MODES

Horizontal:

Samples per division

25 samples / div.

Time/division

Equivalent sampling 50ns to 500ns/div
Real time sampling 1us to 2s/div

Modes

Single, Normal, Auto, Glitch

Accuracy

Real time sampling +/- (0.1% + 0.04 time/div)
Equivalent sampling +/- (0.5% + 0.08 time/div)

Vertical:

Sampling Rate

25 Mega samples per second

Bandwidth (-3dB)

DC Coupled

1:1 shielded test leads ; DC to 10MHz
Coaxial cable (50Ω)

; DC to 20MHz

AC Coupled

1:1 shielded test leads ; 10Hz to 10MHz
Coaxial cable (50Ω)

; 10Hz to 20MHz

Resolution

8 bits

Channel

2

Coupling

AC,DC,GND

460 User s Guide

Introduction

C1-3

Advertising