Test Products International 460 User Manual

Page 9

Advertising
background image

Optional Adapter 3

A296 (AC/DC AMPS)

Range

0 - 400A / 400 - 1000A

Accuracy ( 0 - 400A )

+/- (2.0% + 10 digits , 50 / 60 Hz)

(400 - 1000A)

+/- (2.0% + 10 digits , 50 / 60 Hz)

MULTIMETER MODES

DC Volts (CH1/CH2)

Range

Resolution

Accuracy

400mV

0.1mV

+/- (0.5% + 5 digits)

4V

0.001V

+/- (0.5% + 5 digits)

40V

0.01V

+/- (0.5% + 5 digits)

400V

0.1V

+/- (0.5% + 5 digits)

600V

1V

+/- (0.5% + 5 digits)

AC Volts (CH1/CH2)

Range

Resolution

Accuracy

400mV

0.1mV

20Hz to 50Hz; +/- (2% + 20 digits)

4V

0.001V

50Hz to 1kHz; +/- (1% + 10 digits)

40V

0.01V

1kHz to 20kHz; +/- ( 2% + 10 digits)

400V

0.1V

40Hz to 400Hz; +/- (1% + 10 digits)

600V

1V

40Hz to 400Hz; +/- (1% + 10 digits)

Frequency (CH1/CH2)

Range

Resolution

Accuracy

100Hz

0.01Hz

+/- (1.0% + 10 digits)

1KHz

0.1Hz

+/- (0.5% + 5 digits)

10KHz

1Hz

+/- (0.5% + 5 digits)

100KHz

10Hz

+/- (0.5% + 5 digits)

1MHz

100Hz

+/- (0.5% + 5 digits)

10MHz

1kHz

+/- (0.5% + 5 digits)

20MHz

10kHz

+/- (2.5% + 5 digits)

OHM (CH1 ONLY)

Range

Resolution

Accuracy

400 Ohm

0.1 Ohm

+/- (0.75% + 5 digits)

4k Ohm

1 Ohm

+/- (0.5% + 5 digits)

40k Ohm

10 Ohm

+/- (0.5% + 5 digits)

400k Ohm

100 Ohm

+/- (0.5% + 5 digits)

4M Ohm

1k Ohm

+/- (1.0% + 10 digits)

20M Ohm

10k Ohm

+/- (3.0% + 20 digits)

460 User s Guide

Introduction

C1-5

Advertising