background image

Input impedance

Approx. 1M Ohm

Sensitivity

50mV to 200V/div 1,2,5 sequence

Accuracy

+/- (3% + 0.05 range/div)

Display modes

CH1, Dual

Maximum Input Voltage

600V

Trigger:

Position

Ver 1; Fixed Position / Ver 3; Adjustable Position

Mode

Free run, normal

Source

Internal (CH1/CH2)

Slope

Positive/Negative

Sensitivity

Real time sampling .... 2 divisions or more
Equivalent sampling .... 3 divisions or more

Trend Plot:

Plot Time

30sec/div to 1-hour/div

Plot Data Type

Max / Min Selectable

Temperature Measurement:

Optional Adapter

A301 (k - Type thermocouple)

Range

-40 F to 500 F

Accuracy

+/- (1.5% + 5 digits)

Pressure / Vacuum Measurement:

Optional Adapter

A620

Range

Pressure 500 psi
Vacuum 30 inHg

Accuracy

Pressure +/- (5% + 5 digits)
Vacuum +/- (1.5% + 5 digits)

Current Measurement:

Optional Adapter 1

A251 (AC AMPS)

Range

0 - 40A / 40 - 400A

Accuracy ( 0 - 40A )

+/- (2.0% + 10 digits , 50 / 60 Hz)

(40 - 400A)

+/- (2.0% + 10 digits , 50 / 60 Hz)

Optional Adapter 2

A256 (AC/DC AMPS)

Range

0 - 40A / 40 - 400A

Accuracy ( 0 - 40A )

+/- (2.0% + 10 digits , 50 / 60 Hz)

(40 - 400A)

+/- (2.0% + 10 digits , 50 / 60 Hz)