TROUBLESHOOTING

PROBLEM

cAUSE

POSSIBLE SOLUTION

Motor does not run.

Paint station is not plugged in
On/Off switch in OFF position
Paint station has shut off while under
pressure

No current coming from outlet
Extension cord is damaged or has low
voltage
A fuse has blown on paint station
Motor is not working properly

Make sure unit is plugged in
Turn On/Off switch to ON
Turn the high/low pressure knob to
maximum pressure or release pressure by
turning Prime/Spray lever to Prime
Test the power supply voltage
Replace extension cord

Contact Authorized Service center
Contact Authorized Service Center

Pressure setting is too low

HIGH/LOW pressure control set too
high.

Turn HIGH/LOW pressure control
clockwise

Pump does not prime

Prime/Spray valve is in Spray position

Inlet screen is clogged or intake tube
is not immersed

Inlet valve check ball is stuck

Intake tube is loose

Turn Prime/Spray lever to Prime

Clean debris off inlet screen and make
sure intake tube is at bottom of paint
bucket
Tap firmly on the outside of the inlet valve
with a small wrench, allowing pump to
prime properly

Remove intake tube and place a pencil
into the inlet section to dislodge the ball,
allowing pump to prime properly.

Tighten intake tube with flat-head
screwdriver

Paint station starts but does not
circulate paint when Prime/Spray
lever is turned to Prime

Paint container is empty or intake tube
is not fully submerged in fluid

Suction filter is clogged

Prime/Spray valve is clogged

Fill paint container with material and
submerge intake tube into material

Clean suction filter

Contact Authorized Service Center

Motor seems to be running properly
but pressure drops when pistol-grip
is triggered

Reversible spray tip is worn
Spray tip is clogged
Suction tube and filter are loose or
damaged
Pistol-grip sprayer filter is clogged
Material being sprayed is too thick

Inlet valve is damaged or worn

Intake tube is loose

Replace spray tip
Turn spray tip 180° and spray to clean
Reinstall or replace suction tube and filter
as needed
Clean or replace pistol-grip sprayer filter
Follow material manufacturer’s directions
and thin material as needed
Replace inlet valve

Tighten intake tube

Prime/spray lever is set to spray but
there is flow through the prime tube

Prime/spray lever is dirty or damaged Contact Authorized Service Center

Pistol-grip sprayer leaks

Internal sprayer parts are worn or
damaged

Contact Authorized Service Center

Advertising