Altera MAX 10 Power User Manual

Page 8

Advertising
background image

Figure 2-3: Relationship Between t

RAMP

and POR Delay

Time

POR trip level

Volts

POR delay

configuration
time

tRAMP

first power
supply

last power
supply

Figure 2-4: Simplified POR Diagram for MAX 10 Devices

VCCIO

Modular

Main POR

Main POR

VCCA

VCCIO POR

VCC

VCC POR

VCCA POR

VCCIO

Modular

Main POR

Main POR

VCCA

VCCIO POR

VCC_ONE

VCC POR

VCCA POR

Voltage

Regulator

Single Supply Device

Dual Supply Device

After the MAX 10 device enters user mode, the POR circuit continues to monitor the V

CCA

and V

CC

power supplies. This is to detect a brown-out condition during user mode. If either the V

CCA

or V

CC

voltages go below the POR trip point during user mode, the main POR signal is asserted. When the main

POR signal is asserted, the device is forced into reset state. V

CCIO

(3)

is monitored by the POR circuitry. In

the event of the V

CCIO

(3)

voltage drops during user mode, the POR circuit does not reset the device.

However, if you are using instant-on features, the POR circuit does monitor the VCCIO voltage drop for

up to 9 ms after the last power rail reaches its trip point.

UG-M10PWR

2015.02.09

Power Supplies Monitored and Not Monitored by the POR Circuitry

2-5

MAX 10 Power Management Features and Architecture

Altera Corporation

Send Feedback