Power consumption calculations, Power tab controls – Altera MAX V CPLD User Manual

Page 19

Advertising
background image

Chapter 5: Board Test System

5–5

Using the Board Test System

January 2011

Altera Corporation

MAX V CPLD Development Kit User Guide

Power Consumption Calculations

To calculate the estimated power consumption of the 1.8 VCCINT core power, the
Power

tab uses the following formulas to arrive at the results after clicking Calculate:

Current across Rsense (R44) = Voltage drop across Rsense/Rsense resistance

Power consumption of V

CCINT

= device core voltage (V

CCINT

) × current across

Rsense

For example:

Current across Rsense (R44) = (0.756 mV)/(0.27) = 2.8 mA

Power consumption of V

CCINT

= (1.8 V) × (2.8 mA) = 5.04 mW

You can apply the same formulas to the VARIABLE VCCIO power estimation
calculation:

Current across Rsense (R47) = (0.332 mV)/(0.27) = 1.23 mA

Power consumption of V

CCIO

= (3.3 V) × (1.23 mA) = 4.06 mW

Power Tab Controls

The following sections describe the controls on the Power tab.

1.8 VCCINT

TP1-TP2

—Allows you to enter the value recorded from the multimeter.

Result

—Shows the calculated power consumption after clicking Calculate.

Calculate

—Perfoms calculation for estimated power consumption.

VARIABLE VCCIO

TP3-TP4

—Allows you to enter the value recorded from the multimeter.

VAR VCCIO

—Allows you to select the voltage level that matches the current

setting on J8 on the development board.

Result

—Shows the calculated power consumption after clicking Calculate.

Calculate

—Perfoms calculation for estimated power consumption.