Operating conditions, Operating conditions -3 – Altera USB Blaster User Manual

Page 7

Advertising
background image

Pin

AS Mode

PS Mode

JTAG Mode

Signal Name

Description

Signal Name

Description

Signal Name

Description

7

DATAOUT

Active serial

data out.

nSTATUS

Configuration

status.

8

nCS

Serial

configuration

device chip

select.

9

ASDI

Active serial

data in.

DATA0

Data to device.

TDI

Data to device.

10

GND

Signal ground.

GND

Signal ground.

GND

Signal ground.

Operating Conditions

Use the provided maximum ratings, recommended operating conditions and DC operating conditions to

ensure the correct usage of the USB-Blaster download cable.

Table 2-2: Absolute Maximum Ratings

Symbol

Parameter

Conditions

Min

Max

Unit

V

CC(TRGT)

Target supply voltage

With respect to ground

–0.3

5.5

V

V

CC(USB)

USB supply voltage

With respect to ground

–0.5

6.0

V

I

I

Input current

TDO

or

dataout

–10.0

10.0

mA

I

o

Output current for Rev.

A or Rev. B cable

TCK

,

TMS

,

TDI

,

nCS

,

nCE

–20.0

20.0

mA

Output current for Rev.

C cable

–50.0

50.0

mA

Table 2-3: Recommended Operating Conditions

Symbol

Parameter

Conditions

Min

Max

Unit

V

CC(TRGT)

Target supply voltage,

5.0-V operation

4.75

5.25

V

Target supply voltage,

3.3-V operation

3.0

3.6

V

Target supply voltage,

2.5-V operation

2.375

2.625

mA

Target supply voltage,

1.8-V operation

1.71

1.89

mA

Target supply voltage,

1.5-V operation

1.43

1.57

mA

UG-USB81204

2015.05.04

Operating Conditions

2-3

Specifications for USB-Blaster Download Cable

Altera Corporation

Send Feedback

Advertising