Table 2-4: DC Operating Conditions for USB-Blaster Rev. A and B

Symbol

Parameter

Conditions

Min

Max

Unit

V

IH

High-level input

voltage

V

CC(TRGT)

– 0.2

V

V

IL

Low-level input

voltage

0.15

V

V

OH

5.0-V high-level

output voltage

V

CC(TRGT)

= 4.5 V, I

OH

= 1 mA

4.4

V

3.3-V high-level

output voltage

V

CC(TRGT)

= 3.0 V, I

OH

= 1 mA

2.9

V

2.5-V high-level

output voltage

V

CC(TRGT)

= 2.375 V, I

OH

= 1

mA

2.275

V

1.8-V high-level

output voltage

V

CC(TRGT)

= 1.71 V, I

OH

= 1 mA

1.61

V

1.5-V high-level

output voltage

V

CC(TRGT)

= 1.43 V, I

OH

= 1 mA

1.33

V

V

OL

5.0-V low-level

output voltage

V

CC(TRGT)

= 5.5 V, I

OL

= 1 mA

0.125

V

3.3-V low-level

output voltage

V

CC(TRGT)

= 3.6 V, I

OL

= 1 mA

0.125

V

2.5-V low-level

output voltage

V

CC(TRGT)

= 2.625 V, I

OL

= 1

mA

0.125

V

1.8-V low-level

output voltage

V

CC(TRGT)

= 1.89 V, I

OL

= 1 mA

0.125

V

1.5-V low-level

output voltage

V

CC(TRGT)

= 1.57 V, I

OL

= 1 mA

0.125

V

I

CC(TRGT)

Operating

current (No

Load)

Typical I

CC(TRGT)

= 16 uA

100

uA

Table 2-5: DC Operating Conditions for USB-Blaster Rev. C

Symbol

Parameter

Conditions

Min

Max

Unit

V

IH

High-level input

voltage

V

CC(TRGT)

>= 2.0 V

2.0

V

V

CC(TRGT)

< 2.0 V

V

CC(TRGT)

V

V

IL

Low-level input

voltage

V

CC(TRGT)

>= 2.0 V

0.8

V

V

CC(TRGT)

< 2.0 V

0